QRS Diagnostics SprioCard, Z-7000-0100QRS brings full-function spirometry to off-the-shelf computers and tablets. These spirometers feature portability and accuracy, allowing you to perform spirometry anywhere, anytime. QRS is simplifying spirometry by eliminating the need for calibration and sterilization � everything the patient touches is thrown away!
The SpiroCard� turns an off-the-shelf computer into a full-function spirometer. It exceeds the ATS Guidelines, out-performs competition and eliminates the need for routine calibration.
Standards � The SpiroCard provides effective diagnostic tests and meets the following Standards:
�American Thoracic Society (ATS/ERS) 2005 Standard
�British Thoracic Society (BTS) Standard
�National Institute for Health & Clinical Excellence (NICE) Guidelines
Lung Age Calculation � Lung age is calculated for patients ages 20-84. It is equal to the predicted FEV1 that matches the patient�s actual FEV1. Lung age may differ based on the predicted equation chosen.
Patented, Pre-Calibrated Mouthpiece � The SpiroCard is the only system where everything the patient touches is thrown away. No sterilization or calibration is necessary, saving time for nurses, therapist and physicians.
No Batteries Required � The SpiroCard draws its power from the PC it is connected to via USB port.
The SpiroCard comes equipped with everything you need to begin testing.
� SpiroCard
� QRS Pre-Calibrated Mouthpieces, 2
� Pressure Tubes, 2
� USB Adapter
� Office Medic Software
Also included with the SpiroCard is a three-year warranty.
Weight: 57 grams
Height: 53 mm (w) x 140 mm (d) x 16 mm (h)
Power Supply:Internal: 5Vdc, less than 80 mA. Supplied by the PCMCIA slot.
Range (BTPS):
FLOW: �14 liters/second
VOLUME: 0.5-8 liters
Accuracy (BTPS):
FLOW: �5% of indication or �200 ml/sec, whichever is greater for FEF 25-75 and �10% of indication or �300 ml/s whichever is greater for PEF
VOLUME: �3% of indication or �50 ml, whichever is greater for FVC and FEV1; 10% of indication or �15 L/min, whichever is greater for MVV
Precision (BTPS):
FLOW: 5% of indication or 150 ml/sec, whichever is greater for PEF
VOLUME: 3% of indication or 50 ml, whichever is greater for FVC and FEV1
Calibration: ATS 3-speed or standard calibration check
Predicted Normals:Crapo, Cherniack, Morris, Knudson 1983, Polgar, HSU, Roberts, Warwick, ECCS, NHANES III, Zapletal, Wang, Quanjer
Tests Performed: FVC, Pre/Post Testing, Flow Volume Loop, MVV, SVC
Measuring Time: Up to 30 seconds
Sample Rate: 100 samples/sec
Resolution:
Flow Rate: 2 ml/sec
Volume: 1 ml
Operating Conditions:
Operating Temp: 15-40�C
Humidity: 10-90% (non-condensing)
Atmospheric Pressure: 700-1060 hPa
Storage Conditions:
Temperature: -15-50�C
Humidity: 90% max. (non-condensing)
Atmospheric Pressure: 700-1060 hPa
Parameter |
ATS |
QRS SpiroCard |
FVC Accuracy
FVC Precision
|
3.0%
3.5%
|
Less than 0.2%
Less than 1.3%
|
FEV1 Accuracy
FEV1 Precision
|
3.0%
3.5% |
Less than 0.04%
Less than 1.9%
|
PEF Accuracy
PEF Precision
|
10.0%
5.0%
|
Less than 2.0%
Less than 0.8%
|
*According to LDS Hospital Independent Test 2000; Based upon ATS Standardization Of Spirometry 1994.